80V 60A Programmable Forklift Charger with Cooper Transformer

Product Details
Customization: Available
Material: Carbon Steel
Surface Treatment: Electroplating
Still deciding? Get samples of US$ 689/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
183
Year of Establishment
2007-10-25
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
  • 80V 60A Programmable Forklift Charger with Cooper Transformer
Find Similar Products

Basic Info.

Model NO.
SCR-6-80V 60A
Customized
Customized
Standard
Standard
Transformer
Cooper Transformer
Capacity
80V 60A
Color
Grey/Green
Weight
90kgs
Package Size
60*50*93cm
Programmable
Yes
Control
Silicon Controlled
Transport Package
Wooden Box
Specification
50*40*80CM
Trademark
TORCH
Origin
China
HS Code
8504409990
Production Capacity
5000PCS/Year

Product Description

1. Use of Products
 
charger can meet the charging needs of various types of lead-acid batteries and can be used for normal charging and maintenance charging of electric vehicles, such as forklift, electric flat cars, electric stackers and tourist cars.

2. Product Characteristics

2.1 Touch screen displays charging current, voltage, charging time, charging ampere, charging steps .
2.2 Microprocessor can control the charging process intelligently.
2.3 Constant voltage charging and constant current charging can be realized, and charging process can be edited on touch screen.
2.4 The normal charging and equalized charging can be selected through touch screen. It is easy to operate.
2.5 The charging mode in summer/winter can be selected by touch screen to ensure charging effect at different ambient temperatures.
2.6 The normal charging and equalized charging process can be edited and modified by entering the editing operation password .
2.7 Charging faults can be automatically diagnosed and its corresponding alarm information will be displayed .
2.8 It has the function of adaptive phase sequence of AC power supply and self-recovery of AC power failure.
2.9 It has the functions of over-voltage, over-current, short-circuit protection, transformer temperature, radiator temperature, power supply phase-gap protection.
2.10 Fifty charging records can be recorded and inquired, including date, terminal voltage and accumulative charging capacity.
2.11 Initial charging can be realized by editing the Equalized Charging Process.

3. Input power supply

3.1 Power Supply
This series of chargers use one phase or three-phase power supply.
Three-phase power supply is 110- 600V AC, three fire lines and one ground wire. The grounding wire must be grounded reliably. Charger permits ±5% power supply voltage fluctuation. Within this range, the charging performance and charging time of the charger will not be influenced
3.2 Warning
3.2.1 Charger must be selected according to battery type and capacity (ampere hour Ah). This series of chargers are only suitable for the charging of traction batteries. The batteries can be charged only when they are equipped with electrolyte in a well ventilated environment. If the internal level of the battery drops, the electrolyte should be supplemented appropriately. The wrong choice may lead to excessive gas, boiling and even explosion. Do not charge parallel batteries or batteries that are not allowed to charge.
3.2.2 It is necessary to check whether the battery matches the charger and ensure that the battery is connected to the charger properly during the charging process.
3.2.3 Before using and connecting the charger, please read the instructions for installation and operation carefully, and strictly observe the allowable conditions of use.
3.2.4 Keep all air vent unblocked to prevent overheating; Keep away from various liquids to avoid short circuit.
3.2.5 Charger with high voltage will endanger life safety, only professional and technical personnel can open and repair the charger.
3.2.6 For safety reasons, it is forbidden to make any adjustments and changes to the charger.

4. Technical parameters

Working ambient temperature: - 15 ~45
Relative humidity of environment: <85% (when medium temperature is 20°C±5°C)
Protection Level: IP21
Cooling Mode: Natural Cooling/Forced Air Cooling
Charging Method: Constant Current Charging, Constant Voltage Charging
Charging Function: Normal Charging, equalized Charging, Customized Charging, Summer/Winter Charging Mode
Operational display panel: 4.3 Inch Touch screen, English display.
80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer



5. Test  

80V 60A Programmable Forklift Charger with Cooper Transformer

6. Pacakge 
80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer


7. Delivery
80V 60A Programmable Forklift Charger with Cooper Transformer


8. Workshop


80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer
80V 60A Programmable Forklift Charger with Cooper Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier