200V 50A Redundant Thyristor Charger for Substation Maintenance

Product Details
Customization: Available
Charging Mode: Cc /CV
Protection: Over Current/ Over Voltage/ Short Circuit
Still deciding? Get samples of US$ 5841/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
183
Year of Establishment
2007-10-25
  • 200V 50A Redundant Thyristor Charger for Substation Maintenance
  • 200V 50A Redundant Thyristor Charger for Substation Maintenance
  • 200V 50A Redundant Thyristor Charger for Substation Maintenance
Find Similar Products

Basic Info.

Model NO.
KGCA 200V 50A
Programmable
Yes
Type
Utility Thyristor Redundant
Power
36kw
Input
Single/ Three Phase
Transformer
Cooper Dry
Transport Package
Wooden Box
Specification
200V50A
Trademark
TORCH
Origin
China
HS Code
8504409990
Production Capacity
1000sets /Year

Product Description

  1. Application

KGCA charger is a new type special  charger for battery or for load. Charger contain DC Voltage Regulator, so charger can supply simultaneously to the battery and dc load with power. This system is controlled by digital intelligent with multi charge mode, simple operation and reliability, there is no phase sequence requirement. The transformer is made by high strength paint copper, it can achieve H grade high temperature resistance and isolation, the power units are made by aluminum profile and high-power disc type thyristor units with high performance and reliability.

2  Working conditions

2.1 The sea level of the working site shall not exceed 3000m.
2.2 The ambient temperature ranges from -10ºC to +50ºC.
2.3 The relative humidity is not higher than 95%.
2.4 There is no conductive dust, explosive gas, corrosive gas for metal, infective gas for insulation and steam around the site.
2.5 There is no violent vibration and slope lager than 5°on the site.
2.6 The ventilation on the site must be good.

3  Technical parameters

3.1 Charger technical parameters
3.1.1 Input: three phase AC380V 50Hz(as per customer requirement), the allowable voltage tolerance for the line is ±5%.
3.1.2 power rate 36KVA.
3.1.3 The rated DC output current: 200A.
3.1.4 The rated DC output voltage: 50V.
3.1.5 The rated DC output voltage means the max. charge voltage, if the input AC voltage of the line is 10% lower than the nominal voltage, then the DC output voltage will be lower than rated voltage. The rated DC output current means the max. charge current during operation.
3.1.6 Functions: constant current, constant voltage
3.1.7 The accuracy for constant current: the accuracy for current is less than ±1% when the rated value ranges from 20% to 100%.
3.1.8 The accuracy for constant voltage: the accuracy for voltage is less than ±1% when the rated value ranges from 20% to 100%.
3.1.9 The running mode for the main circuit: three-phase full-bridge controlled rectifier.



 
 4  Working Principle

4.1 Description
There are triangle/star transformers to compose a three-phase full-bridge controlled rectification circuit. In this way it can carry out the  charge function. The contactor will control the conduction angle of the thyristors to change the output voltage and current. The charger contain DC Voltage Regulator, so charger can supply simultaneously to the battery and dc load with power. The fast acting fuse installed on the output terminal of the charger will cut off the DC circuit (main circuit) quickly to protect the batteries and thyristors if there is short circuit in the DC output or batteries.

Two independent chargers , one as main and one as backup.


5.Photos:
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance

6. Details:
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance


7. Testing:
200V 50A Redundant Thyristor Charger for Substation Maintenance

8. workshop:
 200V 50A Redundant Thyristor Charger for Substation Maintenance
200V 50A Redundant Thyristor Charger for Substation Maintenance

9. Delivery:
200V 50A Redundant Thyristor Charger for Substation Maintenance

10. FAQ:

A. Are u manufacturer?
we are Subsidiary of Zibo Torch Energy ( which is a subsidiary of CSSC). Our group company manufacture different kinds of goods. We can sell all the products which are produced by ourself and by our sister companies. Like the machines for battery making, laser machines, charging system,  batteries, material for battery making etc.
B. How long is the warranty?
1 year warranty, and after one year we can provide spare part as per your order.
C. How can we reach your factory?
our Factory locates in ZIBO city, you can take train and reaching ZIBO station , or you can take flight reaching JINAN or Qingdao Airport. We will arrange the pickup.
D. How long is the delivery time?
Usually it depends on your products and the QTY,, the delivery time varies from 3days to 90 days.
E. 
How to pay ?
You can pay to our company account directly with the PI provided by us. We accept TT and L/C.
F. What is the delivery terms?
We can arrange the delivery by sea, by air and by express carrier, Such as DHL, TNT, UPS, Fedex etc. FOB, CFR and CIF are all OK for us. And the nearest port is Qingdao port.  
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier